Description
KEY FEATURES
- dual work opening access for double-sided operation
- simultaneous operation on both sides enhanced workflow
- unique primary containment HEPA filtration system for maximum personnel, product & environment protection
- superior ergonomic design & styling
- negative pressure double-wall housings for containment
- all stainless steel work zone construction
- spacious work zone interior
- smooth & effortless sliding tempered glass window, closes completely
- microprocessor-controlled diagnostic system with digital display & audible alarm
- hourmeter
- delayed-automatic-off timer
- elapsed / event timer
- ISO Class 5 (Class 100) air cleanliness work zone for absolute product protection
- ZERO-LEAK airflow system for enhanced safety
- reliability-proven design & performance
APPLICATIONS
Gelman CytoGuard CDC Dual-Access Series Laminar Flow Cytotoxic Drug Safety Cabinets with its unique primary containment HEPA filtration system meet the needs of pharmacy applications involving the handling of cytotoxic drugs and chemicals that require both containment and aseptic manipulation.
The CytoGuard CDC Dual-Access Series Laminar Flow Cytotoxic Drug Safety Cabinet is an effective laboratory aid in providing
total protection for :
- all personnel and environment from any aerosol, particles or vapours which may be liberated in the preparation, manipulation and dispensing of cytotoxic drugs.
- drug products so that they are prepared or dispensed in an environment free from particulates including biological matters.
- maintenance and testing personnel from exposure to the residue of drug products which may contaminate cabinet filters, mechanical components and other surfaces.
The CytoGuard CDC Dual-Access Series cabinet allows 1 or 2 operators from each side of the cabinet to work simultaneously to enhance workflow.
OPERATION
The CytoGuard CDC Dual-Access Series cabinets provide working access from both sides of the cabinets for one or more users and maintain a minimum average inflow velocity of 100 fpm through the work access openings.
An effective air barrier between the operators and the work zone, maintained by an inflow of room air into the full-width front grilles in the work openings provide personnel and environment protection.
The barrier air blends with the contaminated work area air in a sump beneath the work surface and passes through a primary containment HEPA filter located below the work zone. The filter arrests all particulates released within the work zone, thereby protecting fans, other internal cabinet components, maintenance technicians and the environment from contamination.
The filtered air is partially recirculated back to the work area through a supply HEPA filter on top of the work zone. The recirculated air is HEPA-filtered to create an ultra-clean work
environment for the preparation of drug products.
The remaining filtered air is discharged to the laboratory or outside atmosphere via an exhaust HEPA filter.
The CytoGuard CDC Dual-Access Series cabinets have all contaminated ducts and plenums under negative pressure.
GELMAN ZERO-LEAK airflow system ensures that all positive pressure zones are surrounded by negative pressure zones to contain potentially-hazardous aerosols.
MICROPROCESSOR CONTROL
Microprocessor-controlled diagnostic system with digital display & audible alarm